Insulation Sheet, Sheet Size 36 In. x 48 In., Thickness 1/2 In., Temp. Range -297 Degrees to 220 Degrees F, Color Black, Approx. Range: -297 Degrees to 220 Degrees F Country of Origin (subject to change): United States.
Insul-Tube174; 6’L 5/8″ Nom. I.D 3/8″ Wall Thickness
Insul-Tube 6’L, 5/8″ Nom. I.D, 3/8″ Wall Thickness Powered by Frooition Frooition Frooition | No-js Template | eBay design, eBay store design, eBay shop design, eBay template design, eBay listing design (ver:froo_no_js) This listing is currently undergoing maintenance, we apologise for any inconvenience caused.
K-Flex174; Insul-Sheet174; Roll S2S 1/2″ x 48″ x 70′
K-Flex® Insul-Sheet® Roll S2S 1/2″ x 48″ x 70′.
Insul-Lock174; Self Seal 6’L 5/8″ Nom. I.D 3/8″ Wall Thickness
Insul-Lock Self Seal 6’L, 5/8″ Nom. I.D, 3/8″ Wall Thickness Powered by Frooition Frooition Frooition | No-js Template | eBay design, eBay store design, eBay shop design, eBay template design, eBay listing design (ver:froo_no_js) This listing is currently undergoing maintenance, we apologise for any inconvenience caused.
Insul-Tube174; 6’L 5/8″ Nom. I.D 1/2″ Wall Thickness
Insul-Tube 6’L, 5/8″ Nom. I.D, 1/2″ Wall Thickness Powered by Frooition Frooition Frooition | No-js Template | eBay design, eBay store design, eBay shop design, eBay template design, eBay listing design (ver:froo_no_js) This listing is currently undergoing maintenance, we apologise for any inconvenience caused.
K-Flex 1/2-in x 4-ft Rubber Pipe wrap insulation for 3/4-in Pipe
The K-Flex 1/2-in x 4-ft Rubber Pipe wrap insulation is specifically designed for 3/4-in pipes, providing a reliable and efficient insulation solution for industrial plumbing systems. Made of durable rubber, this insulation helps to maintain water temperature and improve the overall efficiency of the system. Easy to install and long-lasting, it is a valuable addition to any building or industrial facility looking to enhance their plumbing capabilities.
K-Flex 1/4″ ID X 1/2″ Wall x 24″ Long R3.9 1/4″ x 1/2″ A/C Pipe Insulation
K-Flex 1/4″ ID X 1/2″ Thick Wall. Will be at least 2 Feet Long. Commercial Air Conditioning or Refrigeration Pipe Insulation with R3.9 insulating rating. Made in USA. New never installed from HVAC company warehouse stock. Shipping cost and delivery date is calculated by eBay. There are no additional fees added. Normally ship same or next business day. The following technical information is from the K-Flex website – K-FLEX® } INSUL-TUBE® www.kflexusa.com INSUL-TUBE® CLOSED CELL FLEXIBLE ELASTOMERIC FOAM INSULATION DESCRIPTION K-FLEX® INSUL-TUBE® is an NBR/PVC based closed cell, flexible elastomeric foam insulation. It is environmentally friendly as it is free of CFCs, HFCs, HCFCs, PBDEs, formaldehyde and fibers. An EPA-registered antimicrobial agent is incorporated into the product providing additional protection against mold, fungal and bacterial growth. It is UL GREENGUARD® Gold Certified for low VOC emissions. The product’s key physical properties are approved by Factory Mutual. The product is made in K-FLEX® USA’s ISO 9001:2008-certified manufacturing facility in North Carolina. APPLICATION K-FLEX® INSUL-TUBE® is recommended for applications with service temperatures ranging from -297°F (-182°C) to +220°F (+104°C). For applications below -40°F (-40°C), contact K-FLEX® technical support. The product is used to retard heat gain and prevent condensation or frost formation on below-ambient applications, including refrigerant, cold water plumbing, chilled water, and industrial process lines, among others. It can be used with heat tracing tapes. It also retards heat loss from medium hot systems, including hot water plumbing, liquid heating, dual temperature, and solar thermal piping, among others. K-FLEX® USA NBR/PVC elastomeric insulation products can withstand temperature “spikes” up to 250°F (121°C). Because these spikes can vary in temperature and duration, long term effects may vary. Refer to technical bulletin TA36 for additional information. OUTDOOR APPLICATION K-FLEX® INSUL-TUBE® is made from a UV resistant elastomeric blend. For severe UV exposure (rooftop applications) or for optimum performance, K-FLEX® 374 Protective Coating, approved jacketing or K-FLEX® Clad® is recommended. UNDERGROUND APPLICATIONS K-FLEX® INSUL-TUBE® is acceptable for use in buried applications using the same installation principles as above ground applications. For lines above the water table, use a clean fill such as sand (3”-5” layer) to protect the insulation before backfilling. For optimum performance, the lines should be encased in a conduit to protect them from problems associated with ground water intrusion and compaction. If a conduit is not used, the insulation thickness should be increased by one thickness size to compensate for compaction. INSTALLATIONS K-FLEX® INSUL-TUBE® is flexible (even at low temperatures), durable (nonfracturing and skin is resistant to tearing from handling and environment), safe to handle (non-dusting and non-abrasive), and lightweight for an efficient installation. K-FLEX® recommends that insulation is installed on non-operational systems with clean, dry surfaces in ambient conditions between 40°F and 100°F. Properly sized insulation tubing can be slid over piping (tubing should be pushed, not pulled) or, when applied to existing lines, can be slit lengthwise (using a sharp, non-serrated knife) and fitted into place. All seams, butt joints, termination points and open ends should be sealed with an approved contact adhesive, making sure both surfaces to be joined are coated. Longitudinal seams should face downward and vapor stops should be installed as needed. Fittings (elbows, tees, p-traps) and special parts (flanges, valves, etc.) can be field fabricated from insulation tubes and sheets or K-Fit® factory-fabricated fittings can be used. ASTM C1710, Installation Guide for Flexible Closed Cell Foams, and the K-FLEX® Installation Manual should be used as comprehensive installation guides. RESISTANCE TO MOISTURE VAPOR FLOW The expanded closed cell structure and unique formulation inherently resists moisture vapor intrusion and is considered a Class 1 vapor retarder per ASHRAE. For most indoor applications, K-FLEX® INSUL-TUBE® needs no additional protection. Additional vapor barrier protection may be necessary when installed on cold surfaces that are exposed to continuous high humidity. FLAME AND SMOKE RATING K-FLEX® INSUL-TUBE® in wall thicknesses of 2” (50 mm) and below has a flame spread rating of 25 or less and a smoke development rating of 50 or less as tested to ASTM E84, “Surface Burning Characteristics of Building Materials”. It is acceptable for duct/plenum applications, meeting the requirements of NFPA 90A/B. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified when compared to a known standard. Other search descriptions -1/4″ x 1/2″ x 24″1/4″ ID x 1/2″ Wall x 24″ Long1/4″ x 1/2″ x 2 FtKflex
(12) K-Flex Rubber Pipe Insulation 30 LF 1/8 x 2 in Black
ASTM E84 fire-rated for safe use. THIS IS FOR A CASE LOT OF 12. “ THIS IS IN NEW, UNUSED CONDITION.
(2) K-Flex Rubber Pipe Insulation 30 LF 1/8 x 2 in Black
ASTM E84 fire-rated for safe use. “ THIS IS IN NEW, UNUSED CONDITION.
K-Flex 7/8″ ID X 1/2″ Thick Wall x 6′ R3.3 A/C Refrigeration Pipe Insulation
K-Flex 7/8″ ID X 1/2″ Thick Wall. 6 Feet Long. Commercial Air Conditioning or Refrigeration Pipe Insulation with R3.3 insulating rating. Made in USA. New never installed from HVAC company warehouse stock. Shipping cost and estimated delivery date is calculated by eBay. There are no additional fees added. Normally ships same or next business day. The following technical information is from the K-Flex website – 7/8″ x 1/2″ K-FLEX® } INSUL-TUBE® www.kflexusa.com INSUL-TUBE® CLOSED CELL FLEXIBLE ELASTOMERIC FOAM INSULATION DESCRIPTION K-FLEX® INSUL-TUBE® is an NBR/PVC based closed cell, flexible elastomeric foam insulation. It is environmentally friendly as it is free of CFCs, HFCs, HCFCs, PBDEs, formaldehyde and fibers. An EPA-registered antimicrobial agent is incorporated into the product providing additional protection against mold, fungal and bacterial growth. It is UL GREENGUARD® Gold Certified for low VOC emissions. The product’s key physical properties are approved by Factory Mutual. The product is made in K-FLEX® USA’s ISO 9001:2008-certified manufacturing facility in North Carolina. APPLICATION K-FLEX® INSUL-TUBE® is recommended for applications with service temperatures ranging from -297°F (-182°C) to +220°F (+104°C). For applications below -40°F (-40°C), contact K-FLEX® technical support. The product is used to retard heat gain and prevent condensation or frost formation on below-ambient applications, including refrigerant, cold water plumbing, chilled water, and industrial process lines, among others. It can be used with heat tracing tapes. It also retards heat loss from medium hot systems, including hot water plumbing, liquid heating, dual temperature, and solar thermal piping, among others. K-FLEX® USA NBR/PVC elastomeric insulation products can withstand temperature “spikes” up to 250°F (121°C). Because these spikes can vary in temperature and duration, long term effects may vary. Refer to technical bulletin TA36 for additional information. OUTDOOR APPLICATION K-FLEX® INSUL-TUBE® is made from a UV resistant elastomeric blend. For severe UV exposure (rooftop applications) or for optimum performance, K-FLEX® 374 Protective Coating, approved jacketing or K-FLEX® Clad® is recommended. UNDERGROUND APPLICATIONS K-FLEX® INSUL-TUBE® is acceptable for use in buried applications using the same installation principles as above ground applications. For lines above the water table, use a clean fill such as sand (3”-5” layer) to protect the insulation before backfilling. For optimum performance, the lines should be encased in a conduit to protect them from problems associated with ground water intrusion and compaction. If a conduit is not used, the insulation thickness should be increased by one thickness size to compensate for compaction. INSTALLATIONS K-FLEX® INSUL-TUBE® is flexible (even at low temperatures), durable (nonfracturing and skin is resistant to tearing from handling and environment), safe to handle (non-dusting and non-abrasive), and lightweight for an efficient installation. K-FLEX® recommends that insulation is installed on non-operational systems with clean, dry surfaces in ambient conditions between 40°F and 100°F. Properly sized insulation tubing can be slid over piping (tubing should be pushed, not pulled) or, when applied to existing lines, can be slit lengthwise (using a sharp, non-serrated knife) and fitted into place. All seams, butt joints, termination points and open ends should be sealed with an approved contact adhesive, making sure both surfaces to be joined are coated. Longitudinal seams should face downward and vapor stops should be installed as needed. Fittings (elbows, tees, p-traps) and special parts (flanges, valves, etc.) can be field fabricated from insulation tubes and sheets or K-Fit® factory-fabricated fittings can be used. ASTM C1710, Installation Guide for Flexible Closed Cell Foams, and the K-FLEX® Installation Manual should be used as comprehensive installation guides. RESISTANCE TO MOISTURE VAPOR FLOW The expanded closed cell structure and unique formulation inherently resists moisture vapor intrusion and is considered a Class 1 vapor retarder per ASHRAE. For most indoor applications, K-FLEX® INSUL-TUBE® needs no additional protection. Additional vapor barrier protection may be necessary when installed on cold surfaces that are exposed to continuous high humidity. FLAME AND SMOKE RATING K-FLEX® INSUL-TUBE® in wall thicknesses of 2” (50 mm) and below has a flame spread rating of 25 or less and a smoke development rating of 50 or less as tested to ASTM E84, “Surface Burning Characteristics of Building Materials”. It is acceptable for duct/plenum applications, meeting the requirements of NFPA 90A/B. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified when compared to a known standard. Other search descriptions -7/8″ x 1/2″ x 72″7/8″ ID x 1/2″ Wall x 72″ Long7/8″ x 1/2″ x 6 FtKflex